This device that allows the computer to keep running for
at least a short time after the primary power source is disconnect . It also
provides protection from Power Surge.
A UPS has a battery that "kicks in" when the
device experiences electrical damage from the primary source. If you are using
a computer when UPS informs you of the loss of electricity, then you can save
any data you are working on and leave the graceful before leaving the secondary
power source (battery) it happens. When all the power is over, then any data on
your computer's random access memory (RAM) is erased. When a power surge
occurs, a UPS can interrupt the Surge so that it does not damage the computer.
U.P.S. in the data center
Each UPS converts incoming AC to DC through a modifier,
and converts it back with an inverter. Batteries store energy to use in a
utility failure. The power of bypass circuit routes around the rectifier and
inverters, the IT utility runs on incoming utility or generator power. International
Electro technical Commission (IEC) adopted more technically descriptive
terminology in IEC Std.
The voltage and frequency independent (VFI) UPS system is
called dual or double conversion because the incoming AC is rectified in DC to
charge the battery and inverter drive. Inverter creates stable AC power to run
IT equipment.
When the power battery fails, the inverter starts, which
continues to run the information technology (IT) load. When the power is restored,
either by the utility or a generator, the refiner delivers the direct current
(DC) to the inverter as well as recharge the battery. Inverter runs full time.
Utility input is completely different from the output, and the bypass is used
only for maintenance protection or if there is an internal electronics failure.
Since there is no break in power given to IT equipment, therefore vacuum fault
interpreter (VFI) is generally considered to be the strongest form of UPS. Most
systems synchronize output frequency with input, but this is not necessary, so
it is still eligible as frequency frequency .
Every power conversion causes the loss, so waste energy
is historically considered to be the price of the last reliability. The latest
VFI systems claim more efficiency than 96% on almost all loads. Voltage Independient (VI), or True Line Interactive UPS
has a controlled output voltage, but output frequency similar to the input.
Frequency freedom with power is rarely a concern in developed countries.
Utility power directly feeds the output and IT equipment, and the rectifier
keeps the battery charged. Inverter
is similar to output, compensates for voltage dips and acts as an active filter
for voltage spikes and harmonics. Rectifiers and inverter damage are only
occurring when the incoming electricity fluctuates. Flywheel and motor /
generator set are also eligible as VI.
When the incoming power fails, or the voltage gets out of
the range, bypass quickly disconnects from the input and the battery runs
inverter. When the input power is restored, then bypasses the input again,
charging the battery again, and maintaining the output voltage. UPS sellers who
use the same power sources claim to be the loss of reliability. The result is
approximately 98% energy efficiency.
Voltage and frequency dependent (VFD), or standby UPS, is
similar to Operationally VI and sometimes by accidentally called line
interactive. Inverters are discontinued in traditional VFD systems, so it can
take up to 10 to 12 milliseconds (ms) in generating electricity. This brake can
crash the server, so that the VFD can be bad for the UPS data center.
After being activated in the new VFD concepts, the
inverter output power is within 2ms. Bypass
is normally engaged, such as with VI, so the devices are operated directly with
utility or generator. Since the inverter is not working, until the power fails,
there is no voltage control or power consumption, which can increase the
capacity up to 99%. Outside
the boundary, bypassing the input from the power failure or the voltage output
opens the bypass switch; Inverter starts working from the battery. The
rectifier is big enough to keep the battery charged.
What is uninterruptible power supply (UPS) ?
Reviewed by Unknown
on
March 21, 2019
Rating:
![What is uninterruptible power supply (UPS) ?](https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEiooxhSSGmrZTWr2HQKs4zDfB598xoMYcNlFTc-E9d4xF_WdMYakIiszqm2YYKgEA8VbrBHbx1FUTz_AboOGYnJSznf0uiVvcbm06bKDOhvPM4zC1XcumHevVo6fOkq4z7SHBhlw9CNxG0M/s72-c/apc-smart-ups600-watts-1000-vainput-230v-output-230v-interface-port-usb-600x600.jpg)